Materials and engineering Systematic review · 12 observational studies, 223 patients, 285 zirconia bridges · short term
Clinical outcomes of full arch fixed implant-supported zirconia prostheses: A systematic review.
Bidra AS, Rungruanganunt P, Gauthier M. Eur J Oral Implantol 2017. PMID 28944367
What it found: Mean failure rate was 1.4% (four bridges fractured). Prosthetic complications occurred in 16.1% of bridges, and 14.7% were minor complications limited to chipped porcelain veneering.
What it means for you: Zirconia full-arch bridges rarely break outright; when problems happen they are usually chips in the porcelain layer.
Limits: Short-term observational data; the authors say monolithic designs need long-term confirmation.
Materials and engineering Systematic review and meta-analysis · 7 full-arch studies (veneered zirconia) · 5-year estimates
Clinical outcomes of partial and full-arch all-ceramic implant-supported fixed dental prostheses. A systematic review and meta-analysis.
Pieralli S, Kohal RJ, Rabel K, von Stein-Lausnitz M, Vach K, Spies BC. Clin Oral Implants Res 2018. PMID 30306694
What it found: Veneered zirconia full-arch bridges had an estimated 5-year survival of 97.7% and supporting implants 99.4%, but the 5-year complication rate from chipped veneering ceramic was 34.8%.
What it means for you: Porcelain layered over zirconia chips often on full arches. This is one reason many labs now favour monolithic zirconia.
Limits: The authors call the chipping rate clinically unacceptable and ask for more long-term data.
Materials and engineering Systematic review (mainly experimental studies) · 100 papers
Effects of titanium surface topography on bone integration: a systematic review.
Wennerberg A, Albrektsson T. Clin Oral Implants Res 2009. PMID 19663964
What it found: Smooth (Sa under 0.5 µm) and minimally rough (0.5 to 1 µm) surfaces gave weaker bone responses than rougher ones; moderately rough surfaces (over 1 to 2 µm) did better than rough ones (over 2 µm) in some studies. Many papers described surfaces poorly.
What it means for you: Today's moderately rough implant surfaces came out of this line of research.
Limits: Largely animal and laboratory data; inconsistent surface measurements.
Materials and engineering Systematic review · 9 trials, 326 patients, 398 implants · 12 to 60 months
Clinical Outcomes of Zirconia Dental Implants: A Systematic Review.
Pieralli S, Kohal RJ, Jung RE, Vach K, Spies BC. J Dent Res 2017. PMID 27625355
What it found: Ceramic (zirconia) implant survival was 95.6% after 12 months, then an expected decrease of 0.05% a year. Mean bone loss after 12 months was 0.79 mm.
What it means for you: Zirconia implants look promising in the short term, mostly for single teeth and small bridges.
Limits: Short follow-up; few full-arch cases.
Materials and engineering Materials science review
Novel Zirconia Materials in Dentistry.
Zhang Y, Lawn BR. J Dent Res 2018. PMID 29035694
What it found: Yttria-stabilised zirconia (Y-TZP) is the strongest dental ceramic. Newer zirconias trade some strength and toughness for more translucency, for example by adding a cubic phase. Long-term failure mechanisms are not fully explained by routine lab tests.
What it means for you: 'Zirconia' is a family of materials. More see-through grades look more natural but are not as strong.
Limits: Laboratory review; no clinical outcomes.
Materials and engineering Systematic review and meta-analysis · 9 studies, 607 patients, 922 implants · 3 to 36 months
Clinical evidence on titanium-zirconium dental implants: a systematic review and meta-analysis.
Altuna P, Lucas-Taulé E, Gargallo-Albiol J, Figueras-Álvarez O, Hernández-Alfaro F, Nart J. Int J Oral Maxillofac Surg 2016. PMID 26852292
What it found: Narrow titanium-zirconium implants had mean survival and success of 98.4% and 97.8% at one year and 97.7% and 97.3% at two years, with mean bone loss of 0.36 mm at one year and 0.41 mm at two years.
What it means for you: The stronger titanium-zirconium alloy performs well in narrow implants in the short term.
Limits: Short follow-up; narrow implants only; one manufacturer's alloy.
Materials and engineering Animal experiment · 6 miniature pigs, 6 surfaces · 3 and 6 weeks
Influence of surface characteristics on bone integration of titanium implants. A histomorphometric study in miniature pigs.
Buser D, Schenk RK, Steinemann S, Fiorellini JP, Fox CH, Stich H. J Biomed Mater Res 1991. PMID 1918105
What it found: Electropolished and fine-sandblasted surfaces had 20–25% bone-to-implant contact; large-grit sandblasted and plasma-sprayed 30–40%; sandblasted and acid-etched (large grit) 50–60%; hydroxyapatite-coated 60–70%, but the coating showed signs of resorption.
What it means for you: This experiment is the origin of the sandblasted, acid-etched surface used on many implants today.
Limits: Animal study; early healing only; bone contact is not the same as clinical success.
Materials and engineering Systematic review and meta-analysis, 13 studies · 2,841 prostheses, 3,940 implants · 12 to 62 months
Are monolithic zirconia complete arch implant-supported prostheses reliable? A systematic review and meta-analysis.
Matos ACM, Vieira FL, Marrara JR, Tirapelli C, Correia FD, Santiago-Junior JF. J Prosthet Dent 2026. PMID 41813561
What it found: 99% of monolithic zirconia full-arch prostheses were still in function at last follow-up (95% CI 97% to 100%). Pooled technical complication rate was 14%; veneered designs had up to 27% complications against 1% to 3% for monolithic designs.
What it means for you: Unlayered zirconia arches did very well over roughly one to five years. Layered porcelain on top is where most of the trouble sits.
Limits: Mostly retrospective studies; the authors rated the certainty of the evidence as low.
Materials and engineering Network meta-analysis of randomised trials · RCTs published 2009 to 2020 · 12 months after loading
Comparison of external, internal flat-to-flat, and conical implant abutment connections for implant-supported prostheses: A systematic review and network meta-analysis of randomized clinical trials.
Camps-Font O, Rubianes-Porta L, Valmaseda-Castellón E, Jung RE, Gay-Escoda C, Figueiredo R. J Prosthet Dent 2023. PMID 34776267
What it found: Conical connections showed significantly less marginal bone loss and fewer prosthetic complications than external hexagon connections. Connection type did not change implant survival or biological complication rates.
What it means for you: The joint between implant and abutment affects bone levels and screw problems a little, but not whether the implant survives in the first year.
Limits: Only one year after loading.
Materials and engineering Multicentre laboratory study · frameworks tested at three university sites · laboratory
Volumetric determination of the amount of misfit in CAD/CAM and cast implant frameworks: a multicenter laboratory study.
Drago C, et al. Int J Oral Maxillofac Implants 2010. PMID 20862405
What it found: CAD/CAM implant frameworks fitted significantly better onto the implants than frameworks cast with the lost-wax technique.
What it means for you: Milling a framework from a solid block gives a more accurate fit than casting molten metal.
Limits: Laboratory study, not patients.
Materials and engineering In vitro study · titanium and zirconia frameworks on 4 implants · laboratory
In vitro fit of CAD-CAM complete arch screw-retained titanium and zirconia implant prostheses fabricated on 4 implants.
Al-Meraikhi H, et al. J Prosthet Dent 2018. PMID 28720339
What it found: Titanium and zirconia CAD-CAM frameworks fitted equally well. All three-dimensional gaps measured under 135 micrometres, but absolute passive fit was not achieved.
What it means for you: Even milled frameworks are not perfect; the aim is a misfit small enough that the screws and bone are not strained.
Limits: Laboratory model.
Materials and engineering Systematic review and meta-analysis · 25 studies, 2,083 patients, 4,017 implants · 7 studies over 60 months
Clinical outcomes of zirconia implants: a systematic review and meta-analysis.
Mohseni P, Soufi A, Chrcanovic BR. Clin Oral Investig 2023. PMID 38135804
What it found: 10-year cumulative survival was 95.1%. 172 implants failed, 26 of them by fracture (mostly narrow implants). Two-piece implants survived less well than one-piece implants.
What it means for you: Zirconia implants perform well in the studies available, but have far less data than titanium.
Limits: Mostly single crowns and short bridges; few full-arch cases.
Materials and engineering Systematic review and evidence map · 45 reports in 24 study families
Factor-specific clinical evidence for zirconia dental implants: A systematic review and evidence map.
Son K, Lee KB. J Dent 2026. PMID 42810637
What it found: No factor-specific result was independently replicated, so no validated zirconia-specific rule for prognosis or treatment choice could be established.
What it means for you: Claims that one zirconia implant design is better than another are not yet backed by replicated evidence.
Limits: Not prospectively registered; maps evidence rather than pooling it.
Materials and engineering Animal study (dogs) · 20 dogs, 160 devices · 2 hours to 12 weeks
De novo alveolar bone formation adjacent to endosseous implants.
Berglundh T, Abrahamsson I, Lang NP, Lindhe J. Clin Oral Implants Res 2003. PMID 12755774
What it found: New bone began forming in the first week. Between weeks 1 and 2 the bone that gave the screw its initial grip was partly resorbed and replaced with new bone, yet the implants stayed clinically stable throughout.
What it means for you: Healing swaps mechanical grip for biological attachment, which explains the vulnerable window a few weeks after surgery.
Limits: Animal model with a specially designed implant; human timelines differ.
Materials and engineering Prospective clinical study · 20 patients, 27 implants · 10 weeks
Resonance frequency measurement of implant stability in vivo on implants with a sandblasted and acid-etched surface.
Barewal RM, et al. Int J Oral Maxillofac Implants 2003. PMID 14579951
What it found: Measured implant stability was lowest at 3 weeks in all bone types. Soft (type 4) bone showed the largest drop (8.6%) and the largest recovery afterwards (26.9% from week 3 to week 10).
What it means for you: The dip in stability is a normal part of healing, and it is deepest in soft bone.
Limits: Small study of single implants in the back of the jaws.
Materials and engineering Systematic review (mostly case reports) · 9 studies, 21 patients, 33 implants
Titanium hypersensitivity in dental implants: A systematic review of updated clinical evidence and diagnostic strategies.
Restelli L, et al. J Prosthodont Res 2026. PMID 41581901
What it found: Out of 1,761 records only 9 studies qualified; 20 implants were diagnosed as titanium hypersensitivity cases and 17 needed removal. The authors describe the condition as rare but clinically relevant.
What it means for you: True titanium allergy is rare. If you have reacted to metals before, say so; there is no single reliable test yet.
Limits: Case reports only; diagnosis methods were not standardised.
Materials and engineering Retrospective laboratory records study · 2,039 prostheses · 5 years
Survival of 2039 complete arch fixed implant-supported zirconia prostheses: A retrospective study.
Bidra AS, et al. J Prosthet Dent 2018. PMID 28689903
What it found: Mainly monolithic zirconia bridges with porcelain only on the gum area had a 5-year cumulative survival of 99.3%; six fractured. No prostheses came back for chipping of the gum porcelain.
What it means for you: Keeping porcelain off the biting surfaces seems to remove most chipping.
Limits: Data from one laboratory's warranty returns; many prostheses had less than 3 years of service.
Materials and engineering Systematic review · 12 articles, 119 prostheses · 1 to 6 years
Complete-arch implant-supported fixed dental prostheses fabricated with PEEK and PEKK framework: a systematic review.
Mishra SK, et al. Evid Based Dent 2023. PMID 37674039
What it found: PEEK-framework full-arch bridges had 97.3% cumulative survival at short follow-up. Debonding (adhesion) of the veneering was the most common problem.
What it means for you: High-performance polymers are a newer, lighter framework option with limited long-term data.
Limits: Small numbers and short follow-up; very little data on PEKK.
Materials and engineering Systematic review · 10 clinical studies · at least 6 months
Prosthesis wear and complications in various materials used for fixed implant-supported prostheses: A systematic review.
Sanz E, et al. J Prosthet Dent 2026. PMID 41991355
What it found: Wear-related problems (severe wear, chipping, screw loosening, framework fracture) were reported more often in metal-acrylic full-arch bridges. Grinding without a night guard was often linked to more complications.
What it means for you: Acrylic teeth wear; if you grind, a night guard matters whatever the material.
Limits: Few studies measured wear directly.
Materials and engineering Systematic review of laboratory studies · 16 studies
Impact of repeated tightening and loosening on the implant-prosthetic screw joint: A systematic review and meta-analysis.
Shui Y, et al. J Dent 2026. PMID 41203042
What it found: Repeated tightening and loosening reduced the torque needed to remove the screw, with significant loss after 5 cycles and visible wear and deformation after 10.
What it means for you: Screws are wear parts; replacing them rather than reusing them indefinitely is a reasonable habit.
Limits: Laboratory data with high heterogeneity.
Materials and engineering Systematic review of laboratory studies · 10 studies
Effect of three-dimensional print angle on integrity of interim crowns: A systematic review.
Lins LBC, et al. J Prosthet Dent 2025. PMID 39181773
What it found: A 45-degree print angle gave the best fit in most studies; flexural strength results varied widely between studies.
What it means for you: How a printed temporary is made changes its properties, not only the resin chosen.
Limits: In-vitro crowns, not full-arch bridges.
Materials and engineering Laboratory study · 64 specimens · 30 days immersion
Comparative Analysis of Color Stability among 3D-Printed Resin-Based, CAD/CAM, and Conventional Interim Fixed Prosthodontic Materials.
Alshamrani SA, Alobaid BF, Alharkan HM. J Pharm Bioallied Sci 2024. PMID 40061670
What it found: Bis-acryl and 3D-printed interim materials discoloured most, with coffee and tea staining worst. Milled CAD/CAM PMMA and conventional PMMA stayed within clinically acceptable colour change.
What it means for you: Temporary teeth can stain in months; milled PMMA held its colour best in this test.
Limits: Small laboratory study on discs, not on worn bridges.